1. What are the advantages of using natural stone honeycomb panels over traditional stone panels? - Natural stone honeycomb panels are significantly lighter, making transportation and installation easier. - Panels are highly flexible, allowing for custom installations. - It has excellent stability and is resistant to environmental factors and influences. - This panel provides improved sound insulation properties. 2. Can natural stone honeycomb panels be customized to meet specific design requirements? - Yes, customization options for stone type, size, color and thickness are available. 3. What maintenance does natural stone honeycomb panel require? - Panels require minimal maintenance and can be cleaned using traditional stone cleaning products.


Our natural stone honeycomb panels are available in a variety of stone types, sizes and colors, ensuring it will blend seamlessly with any architectural design. The standard thickness is 20mm and can also be customized upon request. The panel offers exceptional stability and is designed to withstand environmental factors such as extreme temperatures, humidity and UV exposure. It is also highly impact resistant and has improved sound insulation properties.| Standard Panel Dimension |
| 600*600mm 600*1200mm 1200*2400mm |
| Panels can be made smaller or larger on request. Note: Not all sizes are available with all stone types. |
| Standard Thickness (5mm Stone+15mm Alu Honeycomb Panel) | Weight(kg/m²) |
| 20mm | 23 (approx – depending on stone type) |
| TECHNICAL DATA | |||||
| NO. | ITEM | STANDARD | TESTED VALUE | RESULT | |
| 1 | Flat Bonding Strength | Average ≥ 1.0 MPa; Minimum ≥ 0.6 MPa | Average 1.31 MPa; Minimum 0.88 MPa | Pass | |
| 2 | Flat Tensile Strength | ≥ 0.8 MPa | 0.91 MPa | Pass | |
| 3 | Flat Tensile Modulus | ≥ 30 MPa | 70.7 MPa | Pass | |
| 4 | Flat Shearing Strength | ≥ 0.5 MPa | 0.54 MPa | Pass | |
| 5 | Flat Shearing Modulus | ≥ 4.0 MPa | 6.43 MPa | Pass | |
| 6 | Bending Strength | ≥ 8.0 MPa | 41.0 MPa | Pass | |
| 7 | Bending Rigidity | ≥ 1.0 x 10^9 N.mm^2 | 2.86 x 10^9 N.mm^2 | Pass | |
| 8 | Shearing Rigidity | ≥ 1.0 x 10^5 N | 4.40 x 10^5 N | Pass | |
| 9 | Climbing Drum Peel Strength | Average ≥ 50N.mm/mm; Minimum ≥ 40N.mm/mm | Average 9.1N.mm/mm; Minimum 42.4NN.mm/mm | Pass | |
| 10 | Fasten Fitter Loading Capacity | ≥ 3.2 kN | 3.2 kN | Pass | |